Code Enforcement Officers have issued the following:
OFFICIAL NOTICE NO. 01-1767UB
Street Address or Location: 1015 Magnolia Dr NW
Contact(s): Juanita Lane
Date Property Inspected: 5/3/2001
Date Notice Issued: 5/8/2001
Violations must be corrected prior to: 7/9/2001
Permit must be obtained by: 6/7/2001
• ELECTRICAL: : Electrical outlet cover missing in kitchen. Electrical outlet not properly installed in basement den. Electrical outlet not ground-fault circuit interrupter (GFI) protected in upstairs bathroom. Electrical outlet within 6 feet of sink not ground-fault circuit interrupter (GFI) protected in kitchen. Electrical switch cover missing in front bedroom, kitchen, and basement bathroom. Light switch missing in rear bedroom. Light fixture not properly installed in basement bathroom. Electrical wiring below 8 feet in height not in conduit in garage, basement bedroom, and basement den. Electrical junction box lacks cover in basement bedroom. Unit lacks direct-wired electrical smoke detector(s). Electrical system must meet required City Electrical Code as determined by the City of Huntsville Inspection Department.
GAS: : Gas system must be checked by licensed gasfitter and approved. Gas system must meet required City Gas Code as determined by the City of Huntsville Inspection Department.
PLUMBING: : Sewer vent cap missing in basement den. Sewer vent cap damaged in garage. Toilet missing in basement bathroom. Plumbing system must meet required City Plumbing Code as determined by the City of Huntsville Inspection Department.
OTHER: : Unit is standing open and is accessible to the public. Exterior trim rotted at front. Windows lack paint or other protective treatment at front and on left side. Exterior trim lacks paint or other protective treatment at front. Window panes broken at front, right, and rear. Window pane missing on left side. Door has hole on left side. Door damaged at front and on left side. Ceilings damaged by smoke in living room, hall, and front bedroom. Walls damaged by smoke in living room, hall, front bedroom, and rear bedroom. Floor rotted in kitchen. Floors not impervious to water in upstairs bathroom and kitchen. Walls have holes in living room, hall, front bedroom, and upstairs bathroom. Walls not in good repair in front bedroom, garage, and basement bedroom. Walls rotted in basement den. Walls damaged in basement den. Ceiling has holes in basement den. Ceiling not in good repair in living room and basement bedroom. Ceiling missing in basement den. Kitchen faucets missing. Water heater lacks T & P valve discharge line in basement den. Door has hole in living room. Door hardware missing in front bedroom. Structure must meet required City Building Code as determined by the City of Huntsville Inspection Department. |
|