Code Enforcement Officers have issued the following:
OFFICIAL NOTICE NO. 22-6255UB
Street Address or Location: 911 PARKLANE AVE NW
Contact(s): Julian Smith
Date Property Inspected: 10/21/2022
Date Notice Issued: 11/21/2022
Violations must be corrected prior to: 1/20/2023
Permit must be obtained by: 12/21/2022
• (7-353) Structure must meet Building Code as determined by the City of Huntsville Inspection Department.
(7-353) Roof rafters and ceiling joists incapable of bearing load: throughout
(7-353) Headed overspanded where larger window was installed.
(7-353) Rafters have no bearing.
(7-353) Rafters and ceiling joist cut or notched too much.
(7-353) Walls removed leaving unsupported rafters and ceiling joist.
(7-353) Removal of a wall and installation of header transferring weight to load point that appears to be causing deflexion in floor joist.
(7-418) Exterior door damaged: front
(7-418) Exterior door has hole: front
(7-417) Door pane broken: front
(7-417) Door pane missing: front
(7-418) Exterior door hardware missing: front
(7-418) Exterior door hardware damaged: front
(7-353) Unit/structure is open and assessable to public.
(7-383i) Unit lacks direct-wired electrical smoke detector(s)(must have on-board battery back-up).
(7-385) Electrical outlet has bare exposed electrical wiring: throughout
(7-385) Electrical switch has bare exposed electrical wiring: throughout
(7-385) Light fixture missing: throughout
(7-385) Splice in electrical wiring must be in approved junction box: throughout
(7-385) Electrical system must meet City Electrical Code as determined by the City of Huntsville Inspection Department.
(7-385) Unit has bare and exposed wiring on exterior: front and rear
(7-383d) Gas system must be checked by licensed gasfitter and inspected by City of Huntsville Inspection Department.
(7-383d) Gas system must meet City Gas Code as determined by the City of Huntsville Inspection Department.
(7-383a) Toilet missing
(7-383d) Water heater missing
(7-383d) Plumbing system must meet City Plumbing Code as determined by the City of Huntsville Inspection Department.
(7-383a) Sewer line lacks trap
(7-422) Interior floor not impervious to water: throughout
(7-422) Interior wall has hole: throughtout
(7-422) Interior wall not in good repair: throughout
(7-422) Interior ceiling has hole: throughout
(7-422) Interior ceiling not in good repair: throughout |
|